3.8 KiB
3.8 KiB
Server Batch Validation Checklist
Use this immediately after moving Nomad, Serenity, and PD. Do not start Google nonsense, SSID cleanup, or extra cleanup until this is green.
Primary control path:
- operator box: Rocinante
- critical dependency group: Nomad + Serenity + PlausibleDeniability
Before the batch
- Rocinante is stable and currently has UniFi/admin access.
- Fallback admin path exists if Rocinante drops off.
- Current port/profile screenshots taken for:
- Port 22 -> Nomad
- Port 24 -> Serenity
- Port 23 -> PD
- Expected target subnet/gateway for Servers VLAN is written down.
- You are ready to unwind in reverse order if needed.
Move order:
- Nomad
- Serenity
- PD
Rollback order if ugly:
- PD
- Serenity
- Nomad
Per-host quick checks during the wave
After Nomad move
- Link came back
- Nomad got expected Servers IP/subnet/gateway
- Rocinante can still reach Nomad
- Expected Nomad-hosted service(s) respond
- No obvious share/dependency explosion yet
After Serenity move
- Link came back
- Serenity got expected Servers IP/subnet/gateway
- Rocinante can still reach Serenity
- Expected Serenity-hosted service(s) respond
- No obvious share/dependency explosion yet
After PD move
- Link came back
- PD got expected Servers IP/subnet/gateway
- Rocinante can still reach PD
- SSH/admin path to PD still works
- Critical PD-hosted homelab services respond
Immediate batch validation
Do all of these before touching anything else:
Reachability
- Rocinante -> Nomad reachable
- Rocinante -> Serenity reachable
- Rocinante -> PD reachable
IP sanity
- Nomad is on the intended Servers subnet
- Serenity is on the intended Servers subnet
- PD is on the intended Servers subnet
- Default gateway is correct for all three
Cross-host dependency sanity
- NFS mounts/shares recovered cleanly
- No host is hanging on stale routes or dead mount targets
- Any name-resolution dependency still works as expected
- No authentication/admin path you need for the rest of the window disappeared
Service sanity
- Doris/dashboard path(s) you need are still reachable
- Any storage-backed services needed for the live window still work
- Nothing critical is stuck waiting on a dead share
Control-plane sanity
- UniFi is still reachable from Rocinante
- Switch/AP visibility still looks normal
- No management-plane surprise coincided with the server batch
Stop conditions
Stop and unwind if any of these are true:
- PD is not reachable from Rocinante
- NFS/share recovery is unclear after a short wait
- You cannot tell whether the problem is routing, DNS, or service binding
- UniFi/admin access is degraded at the same time
- You are guessing instead of validating
Reverse-order rollback strip
If the batch is bad and the reason is not immediately obvious:
- Revert PD port/profile first.
- PD returns to prior lane/profile
- PD admin path restored
- Revert Serenity port/profile second.
- Serenity returns to prior lane/profile
- Revert Nomad port/profile third.
- Nomad returns to prior lane/profile
- Re-check:
- Rocinante -> PD
- Rocinante -> Serenity
- Rocinante -> Nomad
- UniFi/admin access stable again
Do not continue the broader migration until this set is stable.
When this batch counts as successful
- Nomad moved successfully
- Serenity moved successfully
- PD moved successfully
- Rocinante still has the admin path you need
- Shares/services recovered cleanly enough to continue
- No emergency broad firewall workaround was needed
If all six are true, move on. If not, stop pretending and fix or roll back first.